HS-Code
Products
9030100000
1. DEVICES FOR DETECTING OR MEASURING IONIZING RADIATION. SILICON DRIFT DETECTOR SDD (SILICON DRIFTDETECTOR) X-RAY COMPLETE WITH CONNECTION CABLE E-FFC-10P_051 51 MM-1 PCS SERIAL NUMBERS VK5475 VK5481-VK5515 VK5517-VK5520. DO NOT CONTAIN RADIOACTIVE MATERIALS. DESIGNED FOR USE AS PART OF X-RAY FLUORESCENCE SPECTROMETERS DESIGNED TO DETERMINE THE COMPOSITION OF MATERIALS IN THE CIVIL INDUSTRY. ART.KE00-CBN0-H020-ML2C 133 -40PCS. BRAND: KETEKCOUNTRY OF PRODUCTION: DEMANUFACTURER: KETEK GMBH
9022300000
1.WARRANTY REPLACEMENT WITHOUT PAYMENT. X-RAY TUBE USED AS PART OF THE X-RAY FLUORESCENCE SPECTROMETER DESIGNED TO ANALYZE THE CHEMICAL COMPOSITION OF MATERIALS IN THE CIVIL INDUSTRY DOES NOT CONTAIN RADIOACTIVE MATERIALS: ART. TUB00999 -2PCS. TRADEMARK: MOXLITECOUNTRY OF PRODUCTION: USMANUFACTURER: MOXTEK INC
9030100000
1. DEVICES FOR DETECTING OR MEASURING IONIZING RADIATION. SILICON DRIFT DETECTOR SDD (SILICON DRIFTDETECTOR) X-RAY COMPLETE WITH CONNECTION CABLEE-FFC-10P_051 51 MM-1PCS. SERIAL NUMBER VK6214. DO NOT CONTAIN RADIOACTIVE MATERIALS. DESIGNED FOR USE AS PART OF X-RAY FLUORESCENCE SPECTROMETERS DESIGNED TO DETERMINE THE COMPOSITION OF MATERIALS IN THE CIVIL INDUSTRY. ART. KE00-KGN0-H020-ML2C 133 -1PCS. TRADEMARK: KETEKCOUNTRY OF PRODUCTION: DEMANUFACTURER: KETEK GMBH
HS-Code
Products
2818200000
1. ACTIVE ALUMINUM FILTER FLTR SU. 3360/3460/8400 / 860ART.S700117 IS A FILTER IN THE FORM OF A GLASS CYLINDER WITH CONNECTING ELEMENTS ON BOTH SIDES FILLED WITH BALLS OF ACTIVE ALUMINUM. DESIGNED TO ABSORB OIL VAPOR (ABSORPTION). DESIGNED TO FILTER THE AIR CREATING A VACUUM IN THE SPECTRAL CHAMBER OF THE X-RAY FLUORESCENCE SPECTROMETER ARL TO AVOID OIL VAPORS FROM THE PUMP IN THE SPECTRAL CHAMBER. IT IS ESTABLISHED DIRECTLY IN AN AIR HIGHWAY. TRADE MARK: THERMO FISHER. MANUFACTURER: THERMO FISHER SCIENTIFIC. COUNTRY OF MANUFACTURE: CH
8481808700
1.VALVE 20VLV ELM 2 / 2VS R3 / 4 24V 11W 9 SART. A036861 IS A DIAPHRAGM VALVE. INSTALLED IN THE DEVICE ITSELF (NOT ON THE EXTERNAL HIGHWAY). THE WORKING ENVIRONMENT IS AIR. OPENING-CLOSING OF THE PASSAGE SECTION TAKES PLACE BY MEANS OF A MEMBRANE (RUBBER GASKET). IT IS INTENDED FOR REGULATION OF AIR FLOW (CREATION OF VACUUM) IN THE AIR HIGHWAY (OPEN-CLOSED DOES NOT REGULATE PRESSURE) OF THE X-RAY FLUORESCENCE SPECTROMETER ARL. NOT EQUIPPED WITH ANY MEASURING INSTRUMENTS. TRADEMARK: THERMO FISHER. MANUFACTURER: THERMO FISHER SCIENTIFIC. COUNTRY OF MANUFACTURE: NL
4016930090
1.VACUUM EPIPLOON DUCT VAC LIFT 9800ART.S702917IT IS A SPARE PART TO THE SPECTROMETER IN THE FORM OF THE METAL PLUG WITH THE RUBBER CUFF FROM VULCANIZED NONPOROUS RUBBER ESTABLISHED INSIDE. IT IS ESTABLISHED ON A ROD AND MOVES ON IT UP-DOWN KEEPING VACUUM IN ARL SPECTROMETER. USED ONLY IN ARL SPECTROMETERS.-SET OF VACUUM SEALS KIT O-RING 9800ART.S702774 SET OF SEALS FOR VACUUM SYSTEM SPECTROMETER ARL 9800. IS A SET OF RINGS (GASKETS) OF NON-POROUS VULCANIZED RUBBER. SERVE FOR REPLACEMENT OF SEALANTS AT REPAIR OF VARIOUS KNOTS OF THE DEVICE. DOES NOT CONTAIN RADIOACTIVE MATERIALS. - VACUUM EPIPLOON OF DUCT VACUUM PRIMARY CHAMBER ART. S702319IT IS A SPARE PART TO THE SPECTROMETER IN THE FORM OF A METAL SLEEVE WITH A RUBBER CUFF MADE OF VULCANIZED NON-POROUS RUBBER INSTALLED INSIDE. MOUNTED ON THE ROD AND MOVES UP AND DOWN IT MAINTAINING A VACUUM IN THE SPECTROMETER OF THE X-RAY FLUORESCENCE SPECTROMETER
HS-Code
Products
3822000000
CERTIFIED REFERENCE MATERIALS FOR CALIBRATION OF INSTRUMENTS FOR CIVIL USE X-RAY FLUORESCENCE SPECTROMETERS CONSIST OF MINERAL OIL AND COMPONENTS WITH A WELL-DEFINED CONCENTRATION CONOSTAN SULFUR 0 001 10PPM 100G ART 150 400 001 1PC CONOSTAN SULFUR 0 01 100PPM 100G ART 150 1000 002 SST 0ST 1ST 100G ART 150 400 003 1PC CONOSTAN SULFUR 1 00 10 000 PPM 100G ART 150 400 004 1PC CONOSTAN SULFUR 1 5 15 000PPM 100GART 150 400 005 1PC CONOSTAN SULFUR 0 002 20PPM 100G ART 150 400 006 1PC CONOSTAN SULFUR 0 0200 200PPM 100G ART 150 400 007 1PC CONOSTAN SULFUR 2 00 20 000 PPM 100G ART 150 400 008 1PC CONOSTAN SULFUR 0 0025 25PPM 100G ART 150 400 009 1PC CONOSTAN SULFUR 0 025 250 PPM 100G ART 150 400 010 1PC CONOSTAN SULFUR 0 25 2500PPM 100G ART 150 400 011 1PC CONOSTAN SULFUR 2 5 25 000PPM 100G ART 150 400 012 1PC CONOSTAN SULFUR 0 03 300PPM 100GART 150 400 013 1PC CONOSTAN SULFUR 3 00 30 000 PPM 100G ART 150 400 014 1PC CONOSTAN SULFUR 3 5 35000PPM 10 0G ART 150 400 015 1PC CONOSTAN SULFUR 4 00 40 000PPM ART 150 400 016 1PC CONOSTAN SULFUR 4 5 45000PPM 100G ART 150 400 017 1PC CONOSTAN SULFUR 0 005 50PPM 100G ART 150 400 018 1PC CONOSTAN SULFUR 0 050 500 PPM 100G ART 150 400 019 1PC CONOSTAN SULFUR 0 500 5000 PPM 100G ART 150 400 020 1PC CONOSTAN SULFUR 5 00 50 000 PPM 100
9022300000
X-RAY TUBE IS USED AS PART OF AN X-RAY FLUORESCENCE SPECTROMETER DESIGNED TO ANALYZE THE CHEMICAL COMPOSITION OF MATERIALS IN CIVIL INDUSTRY X RAY TUBE W ANODE 40 KV ART TUB00078 W01 30PCS X RAY TUBE ULTRA THIN RHANODE 50 KV ART TUB00076 RH3 15PCS TRADEMARK INC MOROBLITE COUNTRY OF MANUFACTURE MOXLITE COUNTRY OF MANUFACTURE
9030100000
INSTRUMENTS FOR DETECTING OR MEASURING IONIZING RADIATION SILICON DRIFT DETECTOR SDD SILICON DRIFT DETECTOR X-RAYS COMPLETE WITH FROM YEDNUVALNYM CABLES AND CONNECTORS SERIAL NUMBERS VK2039 VK2040 VK2041 VK2042 VK2043 VK2044 VK2046 VK2047 VK2048 VK2049 DOES NOT CONTAIN RADIOACTIVE MATERIALS ARE INTENDED FOR USE IN X-RAY FLUORESCENCE SPECTROMETER INTENDED FOR DETERMINATION OF ARTICLE WAREHOUSE ART KC00 CBN0 H020 ML2C 1 33 1 0PCS TRADEMARK KETEK MANUFACTURING COUNTRY DE MANUFACTURER KETEK GMBH
HS-Code
Products
9022190000
1. EQUIPMENT USING X-RAYS (NON-MILITARY) NOT BELONGING TO SPECIAL MEANS OF UNLOCKING LOCKING DEVICES FOR PENETRATION INTO THE PREMISES STORAGE VEHICLES: PORTABLE X-RAY FLUORESCENT ANALYZER MODEL VANTA VCR-XXX-G2-E COMPLETE WITH PLASTIC INCLUDED ?842655 ART. Q0201052 -1 SET. COMPLETE SET OF ONE DEVICE: - SUITCASE FOR TRANSPORTATION - 1 PIECE; - X-RAY FLUORESCENCE SPECTROMETER OF VANTA MODEL (VCR-XXX-G2-E); - AC ADAPTER FOR DOCKING STATION; - USB CABLE; - LITHIUM-ION BATTERIES - 4 PIECES; - KAPTON PROTECTIVE WINDOWS - 5 PIECES; - USB DRIVE WITH PRODUCT DOCUMENTATION; - X-RAY TRANSLUCENT FILM - 1 SET; - DOCUMENTATION FOR THE END USER -1PC; -CONTROL SAMPLES -2PCS .; - DOCKING STATION -1PC. DESIGNED FOR QUANTITATIVE NON-DESTRUCTIVE ANALYSIS OF THE CONTENT OF CHEMICAL ELEMENTS BY X-RAY FLUORESCENCE SPECTROMETRY IN SAMPLES OF METALS PRECIOUS METALS ALLOYS ORES SOILS LIQUIDS AND POWDERED SAMPLES. TRADEMARK: OLYMPUS COUNTRY OF ORIGIN: US
9022190000
1. EQUIPMENT USING X-RAYS (NON-MILITARY) NOT BELONGING TO SPECIAL MEANS OF UNLOCKING LOCKING DEVICES FOR PENETRATION OF PREMISES STORAGE VEHICLES: PORTABLE X-RAY FLUORESCENT ANALYZER SERIES VANTA C VCR-XXX-A3-O INCLUDING : 822074 ART. Q0202438 -1 SET COMPLETE SET OF ONE DEVICE: - SUITCASE FOR TRANSPORTATION - 1 PIECE - X-RAY FLUORESCENCE SPECTROMETER OF VANTA MODEL (VCR-XXX-A3-O) - AC ADAPTER FOR DOCKING STATION - USB CABLE; - LITHIUM-ION BATTERIES - 4 PIECES; - KAPTON PROTECTIVE WINDOWS - 5 PIECES; - USB DRIVE WITH PRODUCT DOCUMENTATION; - X-RAY TRANSLUCENT FILM - 1 SET; - DOCUMENTATION FOR THE END USER -1PC; -CONTROL SAMPLES -2PCS .; - DOCKING STATION -1PC. DESIGNED FOR QUANTITATIVE NON-DESTRUCTIVE ANALYSIS OF THE CONTENT OF CHEMICAL ELEMENTS BY X-RAY FLUORESCENCE SPECTROMETRY IN SAMPLES OF METALS PRECIOUS METALS ALLOYS ORES SOILS LIQUIDS AND POWDERED SAMPLES. TRADEMARK: OLYMPUS COUNTRY OF ORIGIN: US
9022190000
1. EQUIPMENT USING X-RAYS (NON-MILITARY) NOT BELONGING TO SPECIAL MEANS OF UNLOCKING LOCKING DEVICES FOR PENETRATION OF PREMISES STORAGE VEHICLES: PORTABLE X-RAY FLUORESCENT ANALYZER VANTA VLW-XXX-A1-E-ANALYZER XRF IN THE LAYER. Q0200701 -1??. PORTABLE X-RAY FLUORESCENT ANALYZER VANTAVLW-XXX-CC-E-ANALYZER XRF IN A PLASTIC CASE SERIAL NUMBER 805958 ART.Q0200818 -1PC. COMPLETE SET OF ONE DEVICE: - SUITCASE FOR TRANSPORTATION - 1 PIECE; - X-RAY FLUORESCENCE SPECTROMETER; - AC ADAPTER FOR DOCKING STATION; - USB CABLE; - LITHIUM-ION BATTERIES - 4 PIECES; - KAPTON PROTECTIVE WINDOWS - 10 PIECES; - USB DRIVE WITH PRODUCT DOCUMENTATION; - X-RAY TRANSPARENT PROPYLENE FILM - 1 SET; - DOCUMENTATION FOR THE END USER -1PC; -CONTROL SAMPLES -2PCS .; - DOCKING STATION -1PC. DESIGNED FOR QUANTITATIVE NON-DESTRUCTIVE ANALYSIS OF THE CONTENT OF CHEMICAL ELEMENTS BY X-RAY FLUORESCENCE
HS-Code
Products
9022902000
1. PARTS OF THE LABORATORY X-RAY FLUORESCENCE ANALYZER-SPECTROMETER SIMULTIX 14: -CHANNEL S-PC CL-KA (GE) / CL-KA (GE) S-PCCHANNEL -1 SET; DOES NOT CONTAIN RADIATION SOURCES AND IS USED ONLY IN THE SPECTROMETER SIMULTIX 14 FOR SELECTION OF THE ANALYTICAL LINE ONLY OF THE ELEMENT CHLORINE CL IN THE ANALYSIS OF SAMPLES. TRADEMARK: RIGAKUMANUFACTURER: RIGAKU CORPORATONCOUNTRY OF PRODUCTION: JP
9022902000
1. PART OF X-RAY FLUORESCENCE SPECTROMETER: XRF CONTROL UNIT (BOARD) WITH FIRMWARE FOR NEX-QC PLUS SPECTROMETER (XRF CONTROL BOARD W / FIRMWARE NEX-QC PLUS) CAT.?1002105 -1PC. USED IN THE ELECTRONIC CIRCUIT TO PREPARE THE RECEIVED SIGNAL FOR ANALYTICAL SOFTWARE. THIS BOARD IS DESIGNED TO CONVERT AN ANALOG SIGNAL RECEIVED FROM THE DETECTOR PREAMPLIFIER INTO A DIGITAL SIGNAL THAT IS TRANSMITTED VIA THE RS232 INTERFACE TO THE BILLING UNIT USING A COAXIAL CABLE. BRAND: RIGAKU. MANUFACTURER: APPLIED RIGAKU TECHNOL OGIES INC. COUNTRY OF MANUFACTURE: US.
9022190000
1. EQUIPMENT THAT USES X-RAYS NOT INTENDED FOR MEDICAL USE IS USED TO ANALYZE THE CHEMICAL COMPOSITION OF PETROLEUM OILS FUELS PLASTICS RUBBER TEXTILES METALS AND ALLOYS ETC. IN LABORATORIES OF INDUSTRIAL ENTERPRISES DO NOT CONTAIN RADIOACTIVE MATERIALS: ENERGY DISPERSIVE X-RAY FLUORESCENCE SPECTROMETER RIGAKU NEX QC PLUS EDXRF ANALYZER WHITH ACCESSORIES SER.? QC1977 (AUTOSAMPLER 6-POS FOR 32 MM CUVETTE / 5-POS FOR 40 MM CUVETTE) -1PC. THE ANALYZER WITH ACCESSORIES IS INSTALLED STATIONARY IS NOT A PORTABLE DEVICE IT DOES NOT INCLUDE VIBRATION SENSORS THE PRINCIPLE OF OPERATION IS BASED ON THE VIOLATION OF THE FLUORESCENCE OF ATOMIC SAMPLES AND THE TEST SUBSTANCE BY X-RAY TUBE RADIATION (4W / 50KV). THE ENERGY IS CONVERTED INTO ELECTRICAL PULSES THE AMPLITUDE OF WHICH IS PROPORTIONAL TO THE ENERGY OF THE ABSORBED QUANTA. BRAND: RIGAKU MANUFACTURER: APPLIED RIGAKU TECHNOLOGIES INC. COUNTRY OF MANUFACTURE: US
HS-Code
Products
7326909890
1.CASSETTE CASSETTE 57 D29 W 9400 8600ART.S701558 IS A SPARE PART OF THE X-RAY FLUORESCENCE SPECTROMETER IN THE FORM OF A DETACHABLE CYLINDRICAL STEEL METAL PRODUCT NOT FORGED NOT STAMPED NOT SINTERED. IT IS INTENDED FOR THE MAINTENANCE OF THE ANALYZED SAMPLE ITS LOADING AND UNLOADING IN THE DEVICE.-CASSETTE CASSETTE LARGE UNCODED D29 9800ART.S702573IT IS A SPARE PART OF THE X-RAY FLUORESCENCE SPECTROMETER IN THE FORM OF THE DEMOUNTABLE CYLINDRICAL STEEL METAL PRODUCT NOT FORGED NOT FORGED NOT FORGED. IT IS INTENDED FOR THE MAINTENANCE OF THE ANALYZED SAMPLE ITS LOADING AND UNLOADING IN THE DEVICE. IT IS USED ONLY IN X-RAY FLUORESCENCE SPECTROMETERS ARL-9800/9900. BRAND: THERMO FISHER MANUFACTURER: THERMO FISHER SCIENTIFIC COUNTRY OF MANUFACTURE: CH
8481808700
1.VANNE VALVE A043153 + CONNECTEURART.A043358 IS A DIAPHRAGM VALVE. WORKS IN A GAS ENVIRONMENT. THE FLOW IS OPENED AND CLOSED BY MEANS OF A MEMBRANE (RUBBER GASKET) WHICH IS PRESSED BY THE ROD OF THE ELECTROMAGNET. USED TO OPEN / CLOSE THE GAS CHANNEL IN THE GAS MAIN (SUPPLY OF ARGON OR ARGON-METHANE MIXTURE TO THE SPECTROMETER) X-RAY FLUORESCENCE SPECTROMETER ARL-9800/9900. BRAND: THERMO FISHER MANUFACTURER: THERMO FISHER SCIENTIFIC. COUNTRY OF MANUFACTURE: DE
8413603900
1. THE PUMP WATER PUMP 9800 S / N> 99ART.S702861IS A GEAR VOLUME ROTARY PUMP. DESIGNED FOR PUMPING WATER IN THE COOLING SYSTEM OF THE X-RAY TUBE X-RAY FLUORESCENCE SPECTROMETER. PUMPING IS CARRIED OUT BY MEANS OF ROTATING GEARS. TRADE MARK: THERMO FISHER MANUFACTURER: THERMO FISHER SCIENTIFICCOUNTRY OF PRODUCTION: CH
HS-Code
Products
9033000000
WINDOW MONOCHROMATOR WINDOW KIT FPC PEA6 MONO ART S702854 IS A SPARE PART TO THE X-RAY FLUORESCENCE SPECTROMETER IN THE FORM OF A FRAME INSIDE WHICH IS A THIN PLASTIC AXIAL FILM WITH ALUMINUM COATING IN THE SPECTROMETER OF THE DEVICE IN A VACUUM IS A DETECTIVE SAMPLE FROM THE ANALYTE FROM THE SAMPLE X-RAY THE DETECTOR IS SEPARATED FROM THE ENTIRE SPECTROCHAMBER BY THIS WINDOW AND THE DETECTOR CIRCULATES AN ARGON-METHANE MIXTURE. THUS THE WINDOW SERVES TO SEPARATE THE ARGON-METHANE MIXTURE IN THE DETECTOR FROM THE VACUUM OF THE SPECTROCHAMBER AND PROVIDES PENETRATION THROUGH IT INTO THE DETECTOR UNDISTORTED X-RAY DETECTION. CONTENT OF ONE ELEMENT IN THE SAMPLE APPLICABLE ONLY TO INSTRUMENTS OF THIS TYPE OF X-RAY SPECTROMETERS TRADEMARK THERMO FISHER MANUFACTURER THERMO FISHER SCIENTIFIC COUNTRY OF MANUFACTURE CH
8537109990
BOARD BOARD POWER DITRIBUTION 9900 ART S703652 IS AN ELECTRONIC BOARD DESIGNED TO CONTROL THE POWER SUPPLY OF VACUUM AND WATER PUMPS AS WELL AS THE INCLUSION OF SWITCHING OFF THE EXTERNAL REFRIGERATION MACHINE VOLTAGE 220V USED ONLY IN X-RAY FLUORESCENCE SPECTROMETERS BRAND ARL THERMO FISHER
9033000000
WINDOW MONOCHROMATOR WINDOW KIT FPC PEA9 MONO ART S702989 IS BOTH A SPARE PART TO THE X-RAY FLUORESCENCE SPECTROMETER IN THE FORM OF A FRAME INSIDE WHICH IS A THIN PLASTIC FILM WITH ALUMINUM COATING IN THE SPECTROCHAMBER OF THE DEVICE IN THE VACUUM AND DETECTS FROM X-RAY SAMPLE THE DETECTOR IS SEPARATED FROM THE ENTIRE SPECTROCHAMBER BY A GIVEN WINDOW AND THE ARGON METHANE MIXTURE CIRCULATES IN THE DETECTOR. APPLICABLE ONLY TO INSTRUMENTS OF THIS TYPE OF X-RAY SPECTROMETERS DOES NOT CONTAIN RADIOACTIVE MATERIALS MANUFACTURER THERMO FISHER SCIENTIFIC TRADEMARK THERMO FISHER COUNTRY OF MANUFACTURE OF CH
HS-Code
Products
9022900000
1. PART OF THE X-RAY FLUORESCENCE SPECTROMETER: BLOCK (BOARD) OF THE SIGNAL PROCESSOR PSB SIGNAL PROCESSOR UDXP 8MHZ RSTM -1PC. USED IN THE ELECTRONIC CIRCUIT OF PREPARATION OF THE RECEIVED SIGNAL FOR ANALYTICAL SOFTWARE. THIS BOARD IS INTENDED FOR CONVERSION OF THE ANALOG SIGNAL RECEIVED FROM THE PREAMPLIFIER OF THE DETECTOR IN THE DIGITAL SIGNAL WHICH IS TRANSFERRED THROUGH THE RS232 INTERFACE TO THE SETTLEMENT BLOCK BY MEANS OF A COAXIAL CABLE. BRAND: RIGAKU RIGAKU APPLIED BY NCCOUNTRY OF PRODUCTION: US
9022190000
1. EQUIPMENT THAT USES X-RAYS NOT INTENDED FOR MEDICAL USE IS USED TO ANALYZE THE CHEMICAL COMPOSITION OF PETROLEUM OILS FUELS PLASTICS RUBBER TEXTILES METALS AND ALLOYS ETC. IN LABORATORIESINDUSTRIAL ENTERPRISES: ENERGY DISPERSION X-RAY FLUORESCENCE SPECTROMETER RIGAKU NEX QC PLUS EDXRF ANALYZER WHITH ACCESSORIES SER.? QC1860 + -1PC. THE ANALYZER WITH ACCESSORIES IS INSTALLED STATIONARY IS NOT A PORTABLE DEVICE IT DOES NOT INCLUDE VIBRATION SENSORS THE PRINCIPLE OF OPERATION IS BASED ON THE VIOLATION OF THE FLUORESCENCE OF ATOMS OF THE TEST SUBSTANCE BY X-RAY TUBE RADIATION THE RADIATION OF THE SAMPLE ENTERS THE SEMICONDUCTOR DETECTOR. AMPLITUDE OF WHICH IS THE PROPORTION OF ENERGY ABSORBED QUANTA. BRAND: RIGAKU MANUFACTURER: APPLIED RIGAKU TECHNOLOGIES INC COUNTRY OF MANUFACTURE: US
9022190000
1. EQUIPMENT THAT USES X-RAYS NOT INTENDED FOR MEDICAL USE IS USED TO ANALYZE THE CHEMICAL COMPOSITION OF PETROLEUM OILS FUELS PLASTICS RUBBER TEXTILES METALS AND ALLOYS ETC. IN LABORATORIESINDUSTRIAL ENTERPRISES DOES NOT CONTAIN RADIOACTIVE MATERIALS: ENERGY DISPERSION X-RAY FLUORESCENCE SPECTROMETER RIGAKU NEX DE EDXRF ANALYZER WITH ACCESSORIES SER.? DE 1242 -1PC. THE ANALYZER WITH ACCESSORIES IS INSTALLED STATIONARY IS NOT A PORTABLE DEVICE IT DOES NOT INCLUDE VIBRATION SENSORS THE PRINCIPLE OF OPERATION IS BASED ON THE VIOLATION OF THE FLUORESCENCE OF ATOMIC SAMPLES OF THE TEST SUBSTANCE BY X-RAY TUBE RADIATION THE RADIATION FROM THE SAMPLE ENTERS THE SEMICONDUCTOR DETECTOR. AMPLITUDE TO WHICHPROPORTIONAL ENERGY ABSORBED TO THE GUYS. BRAND: RIGAKU. MANUFACTURER: APPLIED RIGAKU TECHNOLOGIES INC. COUNTRY OF MANUFACTURE: US.
HS-Code
Products
7505210000
CONSUMABLES FOR LABORATORY EQUIPMENT RIGAKU SERVICE SPARE PARTS AND WAVE DISPERSION X-RAY FLUORESCENCE SPECTROMETER SIMULTIX 14 CENTRAL THREAD WIRE CENTER WIRE RT RH 50MKM 200MM ART 902001S DIMENSIONS 50MKM X 200MM -2PCS IS A METAL WIRE FOR THE NICKEL. SPECTROMETER
4016930090
CONSUMABLES FOR LABORATORY EQUIPMENT RIGAKU SERVICE SPARE PARTS AND WAVE DISPERSION X-RAY FLUORESCENCE SPECTROMETER SIMULTIX 14 PRODUCTS MADE OF NON-POROUS NON-SOLID VULCANIZED RUBBER SEALING RINGS IN A VACUUM RING 4DN-36 O-RING 4DN-36 RING 075 100 O-RING 4DG-100 ART 075280S -3PCS IN A VACUUM RING 4DS-25 O-RING 4DS-25 ART 075003S -3PCS VACUUM RING 1AS-025 O-RING 1AS-025 ART RC0000092 -3PCS VACUUM RING 4DP-18 O-RING 4DP -18 A RT 075513S -6PCS VACUUM RING AS568 A-260 O-RING AS568A-260 ART 075282S - 3PCS VACUUM RING AS568A-265 O-RING AS568A-265 ART 075283S -3PCS VACUUM RING 4DG-58 O-RING 4DG-58 ART 0752 79S -16PCS VACUUM RING V-80S O-RIN G V-80S ART 075237S -7PCS VACUUM TO A RING KX-10 O-RING KX-10 ART 077006S - 8PCS VACUUM RING KX-8 O-RING KX-8 ART 077001S -8PCS TOTAL -63PCS USED FOR SEALING THE FILM OF THE DETECTOR OF THE FILM TENSION ON THE COLLIMATOR AND ITS FIXING RUBBER ROLLER RUBER ROLLER ART 237008S -3PCS INSTALLED AS A LIMITER IN THE SYSTEM OF FEEDING THE SAMPLE INTO THE ANALYTICAL CHAMBER OF THE SPECTROMETER
9022190000
EQUIPMENT USING X-RAYS IS NOT INTENDED FOR MEDICAL USE IS USED TO ANALYZE THE CHEMICAL COMPOSITION OF PETROLEUM OILS FUELS PLASTICS RUBBER TEXTILES METALS AND ALLOYS ETC. IN THE LABORATORIES OF INDUSTRIAL ENTERPRISES ENERGY DISPERSION X-RAY FLUORESCENCE SPECTROMETER RIGAKU NEX QC EDCRF ANALYZERS STATIONARY IS NOT A PORTABLE DEVICE DOES NOT INCLUDE VIBRATION SENSORS THE PRINCIPLE OF OPERATION IS BASED ON THE VIOLATION OF THE FLUORESCENCE OF THE ATOMS OF THE SAMPLE OF THE TEST SUBSTANCE BY THE RADIATION OF THE X-RAY TUBE. THE RADIATION FROM THE SAMPLE ENTERS A SEMICONDUCTOR DETECTOR WHERE QUANTA OF DIFFERENT ENERGIES ARE CONVERTED INTO ENERGY. QUANTA
HS-Code
Products
2710199900
1. BASIC OIL BASHNEFT SN150 ACCORDING TO SRT 67826761-001-2014 OIL CONTENT OR OIL PRODUCTS (HYDROCARBONS) OBTAINED FROM BITUMINOUS MINERALS> 70% AS THE MAIN COMPONENT WITHOUT MOLYBDENUM DISULFIDE CONTENT. DOES NOT CONTAIN BIODIESEL. IS NOT A FUEL FRACTIONAL COMPOSITION: AT A TEMPERATURE OF 250 300 350 DEGREES C ACCORDING TO THE METHOD OF ISO 3405-2019 (ASTM D 86-19) CAN NOT BE DETERMINED.ACCORDING TO THE RESULTS OF RESEARCH (APPEARANCE CHEMICAL COMPOSITION) IT IS ESTABLISHED THAT THE PRODUCT SAMPLE IS A CLEAR LIGHT-BROWN THICK OILY LIQUID WITH THE ODOR OF PETROLEUM PRODUCTS WHICH INCLUDES ALIPHATIC AND / OR NAPHTHENIC (NON-AROMATIC) HYDROCARBONS AND A SAMPLE ON A TWIN-X X-RAY FLUORESCENCE SPECTROMETER OF MOLYBDENUM DISULFIDE REVEALED NO TEMPERATURE. C. TO DETERMINE THE FRACTIONAL COMPOSITION OF THE SAMPLE OF GOODS INCLUDING THE PERCENTAGE OF DISTILLATION AT 250 DEGREES C AND 350 DEGREES C IS NOT POSSIBLE BECAUSE IT IS IMPOSSIBLE TO SATISFY THE ABOVE IN IMOGAM GOST 2177-99.FILLING WEIGHT 57520 KG MANUFACTURER: BRANCH OF PJSC ANK BASHNEFT BASHNEFT-NOVOYL . COUNTRY OF PRODUCTION RU. TRADEMARK: NO DATA.
2710199900
1. BASE OIL RESIDUAL SELECTIVE PURIFICATION TU 38.101760-82 WITH CHANGES 1-7. OUT OF SADNESS. OIL CONTENT OR OIL PRODUCTS. (HYDROCARBONS) OBTAINED FROM BITUMINOUS MINERALS> 70% AS THE MAIN COMPONENT WITHOUT MOLYBDENUM DISULFIDE. DOES NOT CONTAIN BIODIESEL. NOT A LIQUID FUEL. ACCORDING TO THE RESULTS OF RESEARCH (APPEARANCE CHEMICAL COMPOSITION) IT IS ESTABLISHED THAT THE PRODUCT SAMPLE IS A TRANSPARENT OILY THICK BROWN LIQUID WITH THE SMELL OF PETROLEUM PRODUCTS WHICH INCLUDES ALIPHATIC AND / OR NAPHTHENIC (NON-AROMATIC) HYDROCARBONS WITH AROMATIC COMPOUNDS AND THE LIKE. THE STUDY ON THE X-RAY FLUORESCENCE SPECTROMETER TWIN-X MOLYBDENUM DISULFIDE WAS NOT DETECTED. FLASH POINT IN OPEN CRUCIBLE 254 DEG. C. DENSITY OF SAMPLES FOR TEMPERATURES 15 DEGREES CELSIUS. IS 900.7 KG / M3. FRACTIONAL COMPOSITION INCLUDING THE PERCENTAGE OF DISTILLATION AT 250 DEG.C AND 350 DEG.C. CANNOT BE DETERMINED. FILLING WEIGHT 179550 KG. MANUFACTURER: LLC NOVOKUYBYSHEVSKY PLANT OF OILS AND ADDITIVES. COUNTRY OF PRODUCTION RU.
2710199900
1. INDUSTRIAL OIL I-40A. TU 0253-043-48120848-2005 WITH CHANGES 1-10 FROM THE SUMS. OIL OR PETROLEUM PRODUCTS (HYDROCARBONS) OBTAINED FROM BITUMINOUS MINERALS> 70% AS THE MAIN COMPONENT WITHOUT MOLYBDENUM DISULFIDE. DOES NOT CONTAIN BIODIESEL. NOT A LIQUID FUEL. IT IS INTENDED FOR APPLICATION IN CARS AND MECHANISMS OF THE INDUSTRIAL EQUIPMENT. ACCORDING TO THE RESULTS OF RESEARCH (APPEARANCE CHEMICAL COMPOSITION) IT WAS FOUND THAT THE PRODUCT SAMPLE IS A CLEAR OILY THICK BROWN LIQUID WITH THE SMELL OF PETROLEUM PRODUCTS WHICH INCLUDES ALIPHATIC AND / OR NAPHTHENIC (NON-AROMATIC) HYDROCARBONS WITH IMPURITIES OF AROMATIC COMPOUNDS ETC .. X-RAY FLUORESCENCE SPECTROMETER TWIN-X MOLYBDENUM DISULFIDE WAS NOT DETECTED. DETERMINE THE FRACTIONAL COMPOSITION OF THE SAMPLE OF GOODS INCLUDING THE PERCENTAGE OF DISTILLATION AT 250; 350 DEG. C IS NOT POSSIBLE BECAUSE IT IS IMPOSSIBLE TO MEET THE ABOVE REQUIREMENTS OF GOST 2177-99. FILLING WEIGHT 58400 KG. MANUFACTURER: LLC NOVOKUY